Description
PyroGuard CRFR™ coveralls are designed to wear over your primary FR garments, helping to extend the life of your primary FR clothing. Coveralls also offer protection from a broad range of chemicals and provide flash fire protection that meets NFPA 2113. Our advanced, self-extinguishing fabric does not melt or drip when ignited to prevent flames from spreading. An attached respirator hood and boots prevent inhalation of toxic chemicals and provide head-to-toe protection. PyroGuard CRFR® Coveralls stop flames and chemicals in their tracks offering the comfort and safety you need to work in tough environments.
Proprietary bi-laminate fabric protects against flames and chemicals
Elastic back stretches with user for more comfort and better tear resistance
Storm flap over zipper adds an extra layer of protection
Details
| Pack Type | Bulk |
|---|---|
| Sterile | No |
| Color | Green |
| Collar / Hood Type | Attached Hood |
| Ankle Style | Attached Boot |
| Cuff Style | Elastic Wrist |
| Material | Bi-Laminate Chemical & Flame Resistant Fabric |
| Seam Style | Taped Seams |
| Closure Type | Zipper w/storm flap |
| Country of Origin | China |
Physical Properties
| Test Conducted | Test Method | Results |
|---|---|---|
| Grab/Tensile - Machine Direction | ASTM D1117 / D1682 | 34 lbs. |
| Grab/Tensile - Cross Direction | ASTM D1117 / D1682 | 27 lbs. |
| Bond Strength - Machine Direction | IST 110.2 | 197 gms |
| Bond Strength - Cross Direction | IST 110.2 | 223 gms |
| Mullen Burst | ASTM D3786-87 | 35 psi |
| Resistivity Machine Direction | IST 70.1 | 2.9 x109 ohms |
| Resistivity | IST 70.1 | 3.1 x109 ohms |
Agent Testing
| CHEMICAL | Penetration ASTM F903 Time to Penetrate (minutes) | Permeation ASTM F739 Normalized Breakthrough (minutes) |
|---|---|---|
| Acetone | >60 | 12 |
| Acetonitrile 90% | >60 | IMB |
| Acetaldehyde | >60 | NT |
| Acrylonitrile | >60 | NT |
| Benzene | >60 | NT |
| Carbon Disulfide | >60 | 9 |
| Crude Oil | >60 | 9 |
| Dichloromethane | 2 | IMB |
| #1 Diesel | >60 | 15 |
| Diethylamine | >60 | IMB |
| Dimethylformamide | <1 | IMB |
| Ethyl Acetate | >60 | 16 |
| Ethylene Dichloride | >60 | NT |
| Ethylene Oxide | >60 | NT |
| Gasoline | >60 | NT |
| Hexane | >60 | >480 |
| Hexamethylene Diisocyanate | >60 | 15 |
| Hydrochloric Acid | >60 | NT |
| JP-8 | >60 | NT |
| Jet Fuel A | >60 | NT |
| Methanol | >60 | IMB |
| Methyl Isobutyl Ketone | >60 | NT |
| Methyl Mercaptan | >60 | NT |
| Monochlorobenzene | >60 | NT |
| Nitric Acid 70% | >60 | 129 |
| Nitrobenzene | 3 | 4 |
| n-Butyl Acetate | >60 | NT |
| Orthodichlorobenzene, Grade F | >60 | NT |
| Para-Dichlorobenzene | >60 | NT |
| Pentane | >60 | NT |
| Phenol | >60 | NT |
| Phosporic Acid 85% | >60 | >480 |
| Sodium Hydroxide 40% | >60 | >480 |
| Styrene | >60 | <1 |
| Sulfuric Acid 96% | 45 | 38 |
| Tetrachlorethylene | >60 | >480 |
| Tetrahydrofuran | <1 | <1 |
| Toluene | >60 | 6 |
| Trichlorobenzene Mixture | >60 | NT |
| Xylene | >60 | NT |
Thermal Properties
| Test Conducted | Test Method | Results |
|---|---|---|
| Vertical Flammability | ASTM 6413 | Pass |
| After Flame | ASTM F1930 | |
| Thermal Protective Performance - Spaced | NFPA 1971 - 97 | 6.8 TPP |
| Thermal Mannequin Test % Body burn - Machine Direction | ASTM 1903 - 3.5 sec. Over Nomex IIIA garment 6.0 oz/yd2 |